Pulse Type |
CHIRP & CW (selectable or auto switching) |
Operating Frequency |
900 kHz |
Beam Width |
2° H, 25° V (+/-3dB) Fan |
Transmit Pulse Length |
500µsec(Chirp), 10 ~ 100µsec(CW) |
Max Range |
60m |
Range Resolution |
7.5mm Max |
Scan Angle |
360° continuous or defined Sector Scan |
Scan Angle Resolution |
0.1125°, 0.225°, 0.45°, 0.9°, 1.8° (selectable) |
Scan Speed |
4sec / 360° @ range 5m, scan resolution 0.9° |
Scan Speed |
6.4sec / 360° @ range 10m, scan resolution 0.9° |
TVG |
60dB |
Gain Control |
-15dB ~ +15dB |
Interface |
RS232 / RS485 up to 3Mbaud |
Power Requirement / Consumption |
12 ~ 60VDC / 4W Max. |
Max Cable Length |
300m @ 2Mbaud, 1km @ 115kbaud |
Connector |
Teledyne Impulse IE55-1206-BCR, Subconn MCIL6M(60cm) |
Operating Depth |
1,000m |
Housing Material |
Alumium (hard anodised) |
Dmensions |
Dia. 64mm, Height 74mm |
Weight |
410g (in air) / 190g (in water) |